Filter Results By:

Products

Applications

Manufacturers

Transformer Test

Measure turns ratio, no-load current and winding resistance of transformers.

See Also: Transformers, Transformer Testers, Current Transformer Test, Current Transformer Test Set


Showing results: 226 - 240 of 391 items found.

  • Test Automation Solution

    CONFORMIQ TRANSFORMER - Conformiq Inc

    Conformiq Transformer shortens the path to test automation, simplifies model-based testing (MBT) adoption using existing methods, and automates manual test execution. Along with Conformiq Creator, which generates executable test cases, scripts and documentation from models, it automates and transforms test design, extending the Conformiq 360° Test Automation™ solution for complex system testing at the speed of development.

  • LCR Meter

    TH2826 - Changzhou Tonghui Electronic Co., Ltd.

    TH2826 series is a new generation impedance test instrument and firstly in conformity with LXI standard inland. It fulfills most low-voltage parameter measurement needs for components and materials with its basic accuracy (0.1%), wide frequency range(from 20Hz to 5MHz). The instrument is widely applied in microphone, resonator, inductor, ceramic capacitor, LCD, varactor and transformer .etc to analyze electrical performance and test low-ESR capacitor and high-Q inductor. With the super high test speed, TH2826 series is especially for frequency response curve analyzing of detector and piezoelectric device on auto production line. Its multiple output impedance mode can be used for different standards of inductor or transformer manufacturers.

  • LCR Meter

    TH2826A - Changzhou Tonghui Electronic Co., Ltd.

    TH2826A is a new generation impedance test instrument and firstly in conformity with LXI standard inland. It fulfills most low-voltage parameter measurement needs for components and materials with its basic accuracy (0.1%), wide frequency range(from 20Hz to 2MHz). The instrument is widely applied in microphone, resonator, inductor, ceramic capacitor, LCD, varactor and transformer .etc to analyze electrical performance and test low-ESR capacitor and high-Q inductor.    With the super high test speed, TH2826A is especially for frequency response curve analyzing of detector and piezoelectric device on auto production line. Its multiple output impedance mode can be used for different standards of inductor or transformer manufacturers.

  • On Load Tap Changer Analyzer

    TAP4 - Zensol Automation Inc.

    The TAP-4 is the first instrument to use vibro-acoustic measurement to perform tests on On-Load Tap Changers (OLTC). The TAP-4 is a universal device, it adapts itself to any type of transformers: MR Reinhausen, ABB, Ferranti, Federal Pioneer and others.

  • Insulating Oil Dielectric Loss Tester

    HDLT - Hention Electrical Equipment Co., Ltd.

    This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Advanced Series - IBEKO Power AB

    TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.

  • Digital ESU Analyzer

    ESU-2050P - BC Group International Inc.

    Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer. The Pulsed Model is compatible with all continuous output generators (same as standard model), plus generators with pulsed output waveforms.

  • Power Calibrator And Protection Relay Test Set

    CP11B - Calmet Smart Calibration Devices

    Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.

  • VLF/DC Hipots

    HVA28 - HV Diagnostics Inc.

    The HVA28 is the smallest, lightest VLF/DC test instrument on the market. It is about as small as you can make it! Do not let its compact size lead you to believe this unit is lacking in power. The instrument can test up to 100,000ft/30kms of cable (at reduced voltage and frequency). In addition to cables, this unit can test vacuum bottles, transformers, motors / generators, cable sheath/shields, etc.

  • Induced Over Voltage Test Set

    NEO TELE-TRONIX PVT. LTD

    We are highly experienced in manufacturing and exporting Induced Over Voltage/DFDV Test Set. It is widely used in electrical and power sector to test different types of transformers. Our range includes different models of testing set to meet clients' diverse requirements. Manufactured in accordance with industry standards, this Induced Over Voltage/DFDV Test Set is offered to clients at competitive price.

  • Insulation Meter

    HT7051 - HT Italia Srl

    HT7051 has been developed to measure insulation resistance with test voltage programmable up to 5kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, electric cables, electric boards, generic devices, etc.) within BT.

  • Current Caliper

    KH23101 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.

  • Current Transformer Comparator

    ZERA® WM3000I - Powermetrix Systems

    The current measuring comparator WM3000I is a high-precision device for comparing secondary outputs from a current transformer under test (or digital output of Electronic CTs or Digital CTs) with a reference signal supplied by a standard transformer primary. The resulting error value will be displayed as ratio error and phase error on the screen. The operation of the comparator will be performed via an integrated 10.1” capacitive touch screen or controlled by PC software. The WM3000I is compatible with existing systems, like Knopp, and exports a data output for active database systems.

  • MCB Magnetic (Instantaneous) Trip Test Bench

    SCR ELEKTRONIKS

    The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!

  • Impulse Voltage And Current Testing

    Shanghai Jiuzhi Electric Co., Ltd.

    Our advanced CDY series Impulse test systems are used for impulse voltage testing of transformers, cables, gas-insulated switchgears (GIS), arresters, and other high-voltage devices. The test systems generate lightning impulse voltage (LI, 1.2/50 µs), chopping lightning impulse voltages (LIC, front time 1.2 µs, front, crest or tail chopped), and switching impulse voltage (SI, 250/2500 µs) in accordance with IEC 60060-1; as well as IEC 60076-3 for transformers, and IEC 62067, 60840 and 60502-1 for cables). By adding extra components, our impulse test system also can generate steeping wave (SWI, >2500kV/ µs) and impulse current (IC, 4/10 µs, 8/20µs, 10/350µs).

Get Help